TERM-009
Weather-resistant intumescent fire-protective coating for steel structures. Applied up to 2000 µm in a single pass, raising fire resistance to 120 minutes.
-
Weather-resistant intumescent fireproof coating for steel structures.
It is a weather-resistant thin-layer fire-protective coating system for steel load-bearing structures that foams under heat during a fire. The fire-resistant low-conductivity foam formed by heat exposure reduces the rate of temperature rise of the load-bearing steel structure. The coating has high stability of properties and a long service life.
The difference from TERM-007 is resistance to direct weather exposure: no protective topcoat is required over TERM-009.
-
– the material is applied up to 2000 µm thick in one pass, reducing labour and time
– low material consumption
– does not create additional static load on structures
– the material is certified in the Republic of Uzbekistan to raise the fire-resistance limit of steel structures up to 120 minutes.
– easy application with airless spray equipment, brush or roller.
– made in Uzbekistan
– weather-resistant grade: needs no protective topcoat on outdoor structures
– the system is one layer shorter — fewer operations on site and less time to handover
-
Used to increase the fire-resistance limit of steel load-bearing structures such as columns, trusses, bracings, struts and other structural load elements.
Intended primarily for structures working outdoors: under atmospheric exposure, high humidity and rural, urban and industrial atmospheric conditions. Indoors it is used in the same way.
The TERM-009 fire-protective topcoat is applied to a surface previously coated with an anti-corrosion primer.
No protective topcoat is required over TERM-009 — the material is weather-resistant in itself. The system consists of two layers: anti-corrosion primer and TERM-009. Compared with TERM-007 that is one technological layer less: fewer operations on site, fewer inter-coat waiting times and less time to handover.
-
Application Steel load-bearing structures: columns, trusses, bracing, struts. Weather-resistant grade Type Weather-resistant thin-film intumescent fire-protective coating Fire resistance Tested in the Republic of Uzbekistan for limits up to 120 minutes Colour Grey Packaging 20 kg Density approx. 1.55 g/cm³ Solids by weight 70 ± 3 % Dry film thickness Depends on the section factor of the steel member; determined by the applicable fire-safety test report. Primer and topcoat thickness is not counted Substrate temperature +5 °C to +40 °C Relative humidity 30–80 % during application; temperature must be 3 °C above the dew point Application method Brush, roller, conventional and airless spray Airless spray Pressure ratio 45:1, pump output 4–5 l/min, nozzle 0.53–0.66 mm, hose over 9.5 mm Drying approx. 24 h per coat at +10…20 °C and 65 % humidity; at least 72 h before applying the topcoat Thinner Fresh water; up to 5 % by weight may be added Shelf life 12 months in unopened factory packaging at +5…+30 °C Tool cleaning Water immediately after use