Stacor Tankguard
Two-component epoxy coating for steel and concrete. High solids content, corrosion resistance in aggressive environments, single-coat application up to 500 µm.
-
Stacor Tankguard is a two-component coating for steel and concrete based on epoxy resin. The coating is chemically resistant to mechanical and chemical effects, wear-resistant, and resistant to vibration and impact.
-
— high solids content
— low material consumption
— excellent corrosion resistance in aggressive media
— single-coat application up to 500 µm
— fast drying
— easy application
— made in Uzbekistan
-
STACOR TANKGUARD is used mainly as an internal coating for steel and concrete tanks for storing flammable liquids (oil, petroleum products, petrol, Jet A1 aviation fuel, vacuum gas oil, diesel fuel), silos, containers, pipes and steel receiving (collecting) sumps in the chemical industry.
-
Purpose Internal lining of steel and concrete tanks for flammable liquids: oil and petroleum products, gasoline, Jet A-1 aviation fuel, vacuum gas oil, diesel fuel; silos, containers, pipes and receiving basins in the chemical industry Type Two-component high-solids epoxy coating resistant to mechanical and chemical attack, vibration and impact Colour Grey; other colours to order Packaging Kit 20 kg: component A — 16 kg, component B — 4 kg Mixing ratio A : B = 4 : 1 by weight Density approx. 1.50 g/cm³ Dry residue by volume 85 ± 3 % Dry film thickness 300 µm per coat Wet film thickness 353 µm per coat Theoretical consumption 0.529 kg/m² at a dry film thickness of 300 µm Surface preparation abrasive blast cleaning to Sa 2½ according to ISO 8501-1 (surface preparation according to ISO 12944-4), cleaning grade 2 according to GOST 9.402, roughness Rz 70…100 µm; concrete — clean and sound substrate, residual moisture max. 4 % Application method brush, roller, air and airless spray; nozzle 0.016…0.018 in, pressure 12…15 MPa Thinner Stacor thinner or equivalent as agreed with the supplier Dilution generally not required, up to 7 % by weight is permissible Pot life approx. 2 hours at +20 °C Next coat after 12 hours at +10 °C, 6 hours at +20 °C, 45 minutes at +60 °C Application temperature from 0 °C to +40 °C; down to −10 °C with winter hardener, drying time increases Relative humidity 30…80 % during application Dew point substrate temperature at least 3 °C above the dew point Shelf life 12 months from the date of manufacture in tightly sealed packaging at −40…+40 °C -
Stacor Tankguard Technical Data Sheet — PDF, revision 09.2026
Техническая инструкция, Russian version — PDF
The document covers the material description, fields of application, surface preparation, mixing ratio, consumption, application conditions and drying times.