Stacor Tankguard

Two-component epoxy coating for steel and concrete. High solids content, corrosion resistance in aggressive environments, single-coat application up to 500 µm.

Stacor Tankguard — комплект из двух компонентов
  • Stacor Tankguard is a two-component coating for steel and concrete based on epoxy resin. The coating is chemically resistant to mechanical and chemical effects, wear-resistant, and resistant to vibration and impact.
  • — high solids content
    — low material consumption
    — excellent corrosion resistance in aggressive media
    — single-coat application up to 500 µm
    — fast drying
    — easy application
    — made in Uzbekistan
  • STACOR TANKGUARD is used mainly as an internal coating for steel and concrete tanks for storing flammable liquids (oil, petroleum products, petrol, Jet A1 aviation fuel, vacuum gas oil, diesel fuel), silos, containers, pipes and steel receiving (collecting) sumps in the chemical industry.
  • PurposeInternal lining of steel and concrete tanks for flammable liquids: oil and petroleum products, gasoline, Jet A-1 aviation fuel, vacuum gas oil, diesel fuel; silos, containers, pipes and receiving basins in the chemical industry
    TypeTwo-component high-solids epoxy coating resistant to mechanical and chemical attack, vibration and impact
    ColourGrey; other colours to order
    PackagingKit 20 kg: component A — 16 kg, component B — 4 kg
    Mixing ratioA : B = 4 : 1 by weight
    Densityapprox. 1.50 g/cm³
    Dry residue by volume85 ± 3 %
    Dry film thickness300 µm per coat
    Wet film thickness353 µm per coat
    Theoretical consumption0.529 kg/m² at a dry film thickness of 300 µm
    Surface preparationabrasive blast cleaning to Sa 2½ according to ISO 8501-1 (surface preparation according to ISO 12944-4), cleaning grade 2 according to GOST 9.402, roughness Rz 70…100 µm; concrete — clean and sound substrate, residual moisture max. 4 %
    Application methodbrush, roller, air and airless spray; nozzle 0.016…0.018 in, pressure 12…15 MPa
    ThinnerStacor thinner or equivalent as agreed with the supplier
    Dilutiongenerally not required, up to 7 % by weight is permissible
    Pot lifeapprox. 2 hours at +20 °C
    Next coatafter 12 hours at +10 °C, 6 hours at +20 °C, 45 minutes at +60 °C
    Application temperaturefrom 0 °C to +40 °C; down to −10 °C with winter hardener, drying time increases
    Relative humidity30…80 % during application
    Dew pointsubstrate temperature at least 3 °C above the dew point
    Shelf life12 months from the date of manufacture in tightly sealed packaging at −40…+40 °C
  • Stacor Tankguard Technical Data Sheet — PDF, revision 09.2026

    Техническая инструкция, Russian version — PDF

    The document covers the material description, fields of application, surface preparation, mixing ratio, consumption, application conditions and drying times.

Telegram WhatsApp

Coverage